{"product_id":"magnetic-resonance-imaging-system-1-5t-mri-machine-16-channel-radiography-imaging-system","title":"Magnetic Resonance Imaging System - 1.5T MRI Machine, 16 Channel Radiography Imaging System","description":"\u003ch3\u003eMagnetic Resonance Imaging System 1.5T MRI Machine, 16 Channel Radiography Imaging System\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e The 1.5T MRI Machine provides both conventional pulse sequences and advanced clinical diagnostic functions, such as 3D angiography and water imaging. Utilizing the new ANKE APEX operating system, it ensures ease of use and rapid diagnosis.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"2\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0584\/9330\/5037\/files\/He54b5d3939834560bee02ae91464cae3v.webp?v=1719710557\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"5\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0584\/9330\/5037\/files\/H9a2cc186d5814341a4c7ed6234beede6Q.webp?v=1719710563\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eReliable short cavity superconducting magnet system with zero liquid helium consumption.\u003c\/li\u003e\n\u003cli\u003eNext-generation fully digitalized and extensible multi-channel spectrometer.\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency and high-fidelity gradient system.\u003c\/li\u003e\n\u003cli\u003eMulti-channel PA RF receiving coil with intelligent identification.\u003c\/li\u003e\n\u003cli\u003eEnglish operating system and highly extensible computer system.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution conventional clinical images.\u003c\/li\u003e\n\u003cli\u003ePractical advanced functional imaging.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eMagnet System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Type:\u003c\/strong\u003e Superconductive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Strength:\u003c\/strong\u003e 1.5T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Method:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShimming Method and Type:\u003c\/strong\u003e Active + Passive + Dynamic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLongest Time of 3D Automatic Dynamic Shimming:\u003c\/strong\u003e 30s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Stability:\u003c\/strong\u003e ≤0.1ppm\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHomogeneity (VRMS Measurement):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e45cm DSV homogeneity (VRMS): ≤0.45ppm\u003c\/li\u003e\n\u003cli\u003e40cm DSV homogeneity (VRMS): ≤0.20ppm\u003c\/li\u003e\n\u003cli\u003e30cm DSV homogeneity (VRMS): ≤0.08ppm\u003c\/li\u003e\n\u003cli\u003e20cm DSV homogeneity (VRMS): ≤0.02ppm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Net Weight (including 100% liquid helium):\u003c\/strong\u003e \u0026lt;4t\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength of Magnet (excluding cover):\u003c\/strong\u003e 157cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength of Magnet (with cover):\u003c\/strong\u003e 170cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Diameter of Magnet:\u003c\/strong\u003e 605mm±5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength of Magnet Scanning Tunnel:\u003c\/strong\u003e 120cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Open Aperture of Magnet:\u003c\/strong\u003e 160cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance from Scanning Couch to Top of Inner Diameter of Magnet:\u003c\/strong\u003e 46cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 Gauss Fringe Field (X, Y, Z axis):\u003c\/strong\u003e ≤2.5m x 2.5m x 4.0m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Capacity of Liquid Helium (100% full):\u003c\/strong\u003e 700L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilling Liquid Helium Period:\u003c\/strong\u003e \u0026gt;3 Years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology of Liquid Helium “Zero” Consumption:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4K Cold Head Technology:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGradient System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Gradient Field (single axis, invalid):\u003c\/strong\u003e 40mT\/m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Gradient Slew Rate (single axis, invalid):\u003c\/strong\u003e 150T\/m\/ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Gradient Rise Time:\u003c\/strong\u003e 0.27ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Gradient Field and Slew Rate Reached at the Same Time:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGradient Cooling System:\u003c\/strong\u003e Water cooling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Digital Real-Time Transmit and Receiving Gradient Control System:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRF System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHead Coil:\u003c\/strong\u003e Yes, 8 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeck Coil:\u003c\/strong\u003e Yes, 8 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Coil:\u003c\/strong\u003e Yes, 16 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnee Coil:\u003c\/strong\u003e Yes, 8 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShoulder Coil:\u003c\/strong\u003e Yes, 4 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnkle Coil:\u003c\/strong\u003e Optional, 8 channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source:\u003c\/strong\u003e Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Metal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf Life:\u003c\/strong\u003e 20 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standard:\u003c\/strong\u003e GB15979-2002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Strength:\u003c\/strong\u003e 1.5T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShimming Method and Type:\u003c\/strong\u003e Active + Passive + Dynamic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e DWI, SWI, inner ear 3D imaging, whole spine imaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoils:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner Diameter of Magnet:\u003c\/strong\u003e 605mm±5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHelium Consumption:\u003c\/strong\u003e 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4K Cold Head Technology:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Gradient Field:\u003c\/strong\u003e 40mT\/m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCenter Frequency:\u003c\/strong\u003e 63.6MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 50\/60Hz, ±1Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source : \u003c\/strong\u003e Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty : \u003c\/strong\u003e 2 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAfter-sale Service : \u003c\/strong\u003e Online technical support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial : \u003c\/strong\u003e Metal\u003c\/li\u003e\n\u003cli data-spm-anchor-id=\"a2700.details.0.i53.1b2667absZd9sF\"\u003e\n\u003cstrong\u003eShelf Life : \u003c\/strong\u003e 20 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrument classification : \u003c\/strong\u003e Class II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety standard : \u003c\/strong\u003e GB15979-2002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Strength : \u003c\/strong\u003e 1.5T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShimming Method and Type : \u003c\/strong\u003e Active + Passive + Dynamic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnology : \u003c\/strong\u003e DWI, SWI, inner ear 3D imaging, whole spine imaging,\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecoils : \u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner diameter of magnet : \u003c\/strong\u003e 605mm±5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ehelium cunsuption : \u003c\/strong\u003e 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4K cold head technology : \u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum gradient field : \u003c\/strong\u003e 40mT\/m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCenter frequency : \u003c\/strong\u003e 63.6MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range : \u003c\/strong\u003e 50\/60Hz,1Hz more or less\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MEUBON","offers":[{"title":"Default Title","offer_id":48270018674740,"sku":"1600540545684","price":600000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0778\/8127\/8516\/files\/Hb59026ec639f4917976ca354c0b1d6925.webp?v=1788280078","url":"https:\/\/meduvon.com\/products\/magnetic-resonance-imaging-system-1-5t-mri-machine-16-channel-radiography-imaging-system","provider":"My Store","version":"1.0","type":"link"}