{"product_id":"optical-coherence-tomography-ophthalmology-oct-machine-for-eye-exam-i-model-mretiview500","title":"Optical Coherence Tomography Ophthalmology OCT Machine for Eye Exam I Model MRetiview500","description":"\u003cvideo height=\"\" width=\"100%\" controls=\"controls\" poster=\"https:\/\/s.alicdn.com\/@sc04\/kf\/He327dc6a018e4f06aaf10c3972be679a0.jpg_720x720q50.jpg\" src=\"https:\/\/video01.alibaba.com\/vod-icbu\/4f4e1c368ac918af\/00d976042667bbc1\/20230516_4c4133e32009ec1b_409652860829_mp4_264_sd_unlimit_taobao.mp4?w=960\u0026amp;h=540\u0026amp;e=sd\u0026amp;t=2101ee8d16997135150888281e35c3\u0026amp;b=icbu_video\u0026amp;p=*_icbu_vod_publish\u0026amp;tr=mp4-264-sd-unlimit\"\u003e\u003c\/video\u003e\u003cbr\u003e\n\u003cp data-spm-anchor-id=\"a2700.details.0.i93.5dda225fccFmRD\"\u003e\u003cspan data-spm-anchor-id=\"a2700.details.0.i92.5dda225fccFmRD\" style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003eOur Retiview500 optical coherence tomography OCT machine is an ophthalmic device for comprehensive eye exam, such as macular, retina problems or diseases, glaucoma, and so on. It is based on high sensitivity spectral domain technology to obtain high-resolution 3D retinal tomography images with high accuracy. It is fully automatic, simple and fast to operate. It provides several types of professional test reports to meet different examination requirements.\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-spm-anchor-id=\"a2700.details.0.i94.5dda225fccFmRD\" style=\"margin-top: 5px; margin-bottom: 10px; word-break: break-word; line-height: 1.5; width: 1139.1px; font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003eIt is simple to operate. After inputting the patient information, the “one-key take picture” feature allows the operator to capture the images with a simple touch. With this feature, the device will automatically align the pupil, focus and capture the OCT images of both eyes.\u003c\/p\u003e\n\u003cp data-spm-anchor-id=\"a2700.details.0.i102.5dda225fccFmRD\" style=\"margin-top: 5px; margin-bottom: 10px; word-break: break-word; line-height: 1.5; width: 1139.1px; font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003eFor a complicated situation or skilled operators, the RetiView500 provides semi-automatic and manual modes, allowing a deeper operation experience.\u003c\/p\u003e\n\u003cp data-spm-anchor-id=\"a2700.details.0.i93.5dda225fccFmRD\"\u003e \u003c\/p\u003e\n\u003cp data-spm-anchor-id=\"a2700.details.0.i95.5dda225fccFmRD\" style=\"margin-top: 5px; margin-bottom: 10px; word-break: break-word; line-height: 1.5; width: 1139.1px; font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003eThe RetiView500 has powerful accurate analysis software. For each scanning mode, the RetiView500 provides a customized analysis function. The software can accurately segment 10 retina layers. The system also provides binocular comparison analysis, single eye follow-up analysis, glaucoma and other progress analysis, giving a strong quantitative analysis for clinic diagnosis of various eye diseases.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-spm-anchor-id=\"a2700.details.0.i103.5dda225fccFmRD\"\u003e\n\u003cstrong\u003eModel Number : \u003c\/strong\u003e Retiview500 OCT Machine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethodology : \u003c\/strong\u003e Spectral domain OCT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAxial resolution : \u003c\/strong\u003e ≤ 6 um (in tissue)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse resolution : \u003c\/strong\u003e -≤ 20 um (in tissue)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan depth : \u003c\/strong\u003e ≥ 2.5 mm (in air)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan range : \u003c\/strong\u003e ≥ 6 mm\u003c\/li\u003e\n\u003cli data-spm-anchor-id=\"a2700.details.0.i96.5dda225fccFmRD\"\u003e\n\u003cstrong\u003eScan modes : \u003c\/strong\u003e 30, Raster, Circle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli data-spm-anchor-id=\"a2700.details.0.i96.5dda225fccFmRD\"\u003e\n\u003cstrong style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\"\u003eFeatures:\u003c\/strong\u003e\u003cbr style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\"\u003e\u003cspan data-spm-anchor-id=\"a2700.details.0.i97.5dda225fccFmRD\" style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003e1. The RetiView500 provides a rich analysis software package with an automatic platform.\u003c\/span\u003e\u003cbr style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\"\u003e\u003cspan data-spm-anchor-id=\"a2700.details.0.i98.5dda225fccFmRD\" style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003e2. The RetiView500 offers a special “one-key operation ”mode which makes the captures simple and fast.\u003c\/span\u003e\u003cbr style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\"\u003e\u003cspan data-spm-anchor-id=\"a2700.details.0.i99.5dda225fccFmRD\" style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003e3. The RetiView500 dramatically reduces the learning time and improves the success rate and your working efficiency.\u003c\/span\u003e\u003cbr style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\"\u003e\u003cspan data-spm-anchor-id=\"a2700.details.0.i100.5dda225fccFmRD\" style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003e4. The RetiView500 has a compact design with a built-in computer which effectively saves space. The compact design also makes the shipment and movement easier.\u003c\/span\u003e\u003cbr style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\"\u003e\u003cspan style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003e5. The installation-free concept allows the immediate use of the device after connecting-the power cable and switching on the power.\u003c\/span\u003e\u003cbr style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\"\u003e\u003cspan style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003e6. The 13.3 inch touch screen allows easy operation with your finger and adjusting of the scanning parameters .\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 5px; margin-bottom: 10px; word-break: break-word; line-height: 1.5; width: 1139.1px; font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"\u003e\u003cspan style=\"display: inline-block; word-break: break-word; font-size: 14px;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"max-width: 1200px; min-width: 60%; margin-bottom: 20px; table-layout: fixed; word-break: break-all; height: auto; font-family: roboto, Helvetica, Arial, Verdana, Tahoma; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; border-color: #dddddd;\" cellpadding=\"2\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eMethodology\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eSpectral domain OCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eAxial resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e≤ 6 µm (in tissue)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eTransverse resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e≤ 20 µm (in tissue)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eScan depth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e≥ 2.5 mm (in air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eScan range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e≥ 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eScan speed\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e≥ 24,000 A-scans\/sec, up to 36,000 A-scans\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eScan modes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e30, Raster, Circle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eFundus image\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eOCT en face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eFocus adjustment\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e-150 to 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003ePupil diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e≥ 3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eOCT light source\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e840 nm SLD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eOptical power\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e750 µW (at cornea)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e13.3’’touch screen, optional external mouse or keyboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e100-240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eDimensions \u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e497 mm × 395 mm × 490 mm (L× W × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important; background-color: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eLED dot matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"width: auto !important; height: auto !important;\"\u003e\n\u003ctd style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003eExternal fixtion\u003c\/td\u003e\n\u003ctd data-spm-anchor-id=\"a2700.details.0.i101.5dda225fccFmRD\" style=\"padding: 10px; border-width: 1px; border-color: #dddddd; word-break: break-all; min-width: 1px; width: auto !important; height: auto !important;\"\u003e75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-family: roboto, Helvetica, Arial, Verdana, Tahoma;\" face=\"roboto, Helvetica, Arial, Verdana, Tahoma\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"MEUBON","offers":[{"title":"White","offer_id":48269988429876,"sku":"62014465210","price":23500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0778\/8127\/8516\/files\/optical-coherence-tomography-ophthalmology-oct-machine-for-eye-exam-i-model-mretiview500-884.webp?v=1788279616","url":"https:\/\/meduvon.com\/products\/optical-coherence-tomography-ophthalmology-oct-machine-for-eye-exam-i-model-mretiview500","provider":"My Store","version":"1.0","type":"link"}