Experience unparalleled efficiency and accuracy with our High Performance Chromatograph Insulating Transformer Oil Analysis System featuring a Dissolved Gas Analyzer.

Explore its advanced features:

  1. Effortless Connectivity: Utilizes a cutting-edge 10/100m adaptive Ethernet communication interface and built-in IP protocol stack for seamless long-distance data transmission over enterprise Intranet and Internet, simplifying laboratory setup and analysis data management.

  2. Real-time Monitoring: Three separate connections enable local processing site, unit director, and supervisor to monitor instrument operation and analysis data in real-time, enhancing supervision and control.

  3. Multi-Chromatograph Support: NetChromTM workstation supports multiple chromatographs simultaneously, streamlining data processing, control, and document management to reduce laboratory investment and operating costs.

  4. User-Friendly Interface: Offers operating systems in Chinese and English, allowing users to switch as needed for convenience.

  5. Customizable Temperature Control: Users can freely name temperature control areas for ease of use.

  6. Robust Performance: Features multi-processor parallel operation for stability and reliability, accommodating complex sample analysis with up to four detectors, including FID, TCD, ECD, FPD, and NPD.

  7. Modular Design: Modular structure facilitates easy replacement and upgrade, safeguarding investment effectiveness.

  8. Precision Temperature Control: Incorporates a new microcomputer temperature control system with high accuracy and reliability, featuring a six-way independent temperature control system for versatile sample analysis.

  9. Digital Control Enhancements: Can be paired with advanced electronic flow controller (EFC) and electronic pressure controller (EPC) for improved reproducibility of qualitative and quantitative results.

  10. Programmable Operation: Designed with timing and self-starting program for seamless online gas sample analysis with an optional on-line automatic sample injection unit.

  11. User-Friendly Operation: Simple keyboard-controlled microcomputer interface with automatic detector identification, fault diagnosis, and power-off data protection for hassle-free operation.

  12. High-Resolution Signal Processing: Equipped with built-in low noise, high resolution 24-bit AD circuit with baseline storage and deduction functionality.

  13. Compatibility: Supports Windows XP, Windows 2000, Windows 7, and other operating systems, storing sample data in CDF files compatible with leading chromatography workstations.

  14. Versatile Connectivity: Features MODBUS/TCP standard interface for easy integration with Distributed Control Systems (DCS) and other external systems.

  15. Wide Compatibility: Compatible with automatic injectors from various manufacturers for enhanced flexibility and convenience in sample handling.

Specifications

  • Operating Display: 192×64 lattice sinicized liquid crystal
  • Temperature Control Domain: 6 routes
  • Temperature Range: Indoor temperature +5℃ to 400℃, increment: 1℃, Precision: ±0.1℃
  • Temperature Program Order: 16 steps
  • Heating Rate: 0.1 to 40℃/min
  • Pneumatic Control: Mechanical valve control mode, electronic pressure flow control mode, any optional
  • External Events: 4 routes
  • Sample Injector Species: Fill column, capillary, six-way valve gas injection, automatic headspace injection, etc., optional
  • Detection Configured: 5 Entries (FID, TCD, ECD, FPD, NPD optional)
  • Sample Start: Manual or self-motion, any selection
  • Communication Port: Ethernet: IEEE802.3
  • Gross Weight of the Host: 59kg
  • Host Volume: 706065cm^3
  • Oscillation Device:
    • Gross Weight: 88lbs
    • Volume: 614657cm^3
  • Air Gas Generator:
    • Gross Weight: 88lbs
    • Volume: 654077cm^3
  • Hydrogen Generator:
    • Gross Weight: 46lbs
    • Volume: 533655cm^3
  • Gas Cylinders:
    • Gross Weight: 38lbs
    • Volume: 9621.521.5cm^3

Unlock the full potential of chromatographic analysis with our state-of-the-art system designed for precision and reliability.

  • Warranty : 1 Year
  • Display : 192*64 LCD
  • Temperature Control Area : 6 Loops
  • Temperature Control Range : Room Temperature: +5~400
  • Programmed Temperature Order : 16
  • External : 4 Loops
  • Number of Detectors : >40db
  • dimension : Fid, Tcd, Ecd, Fpd, Npd (Optional)
  • Start Sampling : Manual, Auto

MEUBON

High Performance Chromatograph: Insulating Transformer Oil Analysis System with Dissolved Gas Analyzer | Accurate Monitoring & Analysis for Transformer Maintenance

Regular price $35,000.00 USD
Regular price $37,960.00 USD Sale price $35,000.00 USD
SALE SOLD OUT

Quality Products from Trusted Suppliers

30 Day Money Back Guarantee

Buy From A Reputable USA Company

Safe Secure Payments

Why choose us?

  • Worldwide Fast Delivery
  • 24/7 Customer Service
  • Secure Payment
View full details

We’re committed to ensuring you find the perfect fit with every purchase. Our dedication to quality and precision means you can shop with confidence, knowing that our pieces are crafted to suit you perfectly. If you’re not completely satisfied, we offer a hassle-free return policy